Hand held BD5w series Multi-sensors
for lab and field smart test
of
pH, conductivity /salinity, DO, Turbidity
and other electro-chemical parameters
Ref: HBD5WMSIntE
Date:2002-05-23
![]()
l
Easy-to-use and Smart
Test
l
high and low alarm
limits and display hold
l
2x16 LCD Display,5x4
Keypad
l
Known Addition, TKA
Methods
l
8 Standards
Calibration for Turbidity and SCT
l
Automatic Blank
Correction
l
Datalog,
Readout and Print out support
l
Communication to PC
Acquisition System, by STIMcom/Modbus in accordance with IEEE 1451.2 STIM
protocol
![]()
Advanced instrumental features include calibration
edit, and temperature -compensated ISE measurement. Use calibration edit to
review, delete or re-measure calibration standards.
HBD5WMS
Handheld instruments has capability to test up to 45 water quality parameters with single probe
replaceable, and offering temperature compensation as well.
Ease of operation, data display and retrieval, and
advanced analytical techniques for performing sophisticated analyses make the HBD4/5w
the best choice for the multi-user lab and research chemist, as well to field
patrol.
Versatile Single Channel, Multi Parameter
System
|
n
n
Field-replaceable
ISE, Galvanic, conductivity and turbidity n
User setup
unit, mV, pH, mg/L etc. n
RS-232 and
Compatible with IEEE 1451.2 STIM data analysis software n
Easy-to-use,
screw-on sensor replacement n
IAP user-upgradeable
software via internet or peer to peer support n
5 year
warranty on the instrument; 1-year on the probe module and cables n
Available
with 1.3m cable default (user order specification acceptable) n
Stores
over 3,000 frame datalog, time and date stamped |
|
|
||||
|
|
Support
H-series conductivity and turbidity sensors, and any other ISE sensors. Even
from other manufacturers worldwide, just need to connect according the
instructions |
|
|||
|
Specifications: |
|
|
|||
|
Analog Test
Resolution: |
16-24 bits,
equal to better than ppm to 100% |
|
|||
|
Auto range:
-1.25 to +1.25V scale |
No any
operation to switch range |
|
|||
|
Environ
Temperature |
-10 to 50 °C |
|
|||
|
Environ
Humidity |
10 to 90%RH |
|
|||
|
Supply |
Lithium
Rechargeable Cell or DC6-24V Source |
|
|||
|
Size(Analyzer
only) |
98W×180H×35D
(mm) |
||||
|
Weight (net) |
0.5 kg |
||||
|
Parameters |
Descriptions |
|
DO3230 Dissolved
Oxygen Sensor |
Galvanic Cell |
|
Range: |
0 to 500% air
saturation; 0 to 50 mg/L |
|
Accuracy: |
0 to 200% air
saturation, ± 2% of the reading or 2% air saturation; whichever is greater |
|
Resolution: |
0.1% air
saturation; 0.01 mg/L |
|
Sensor Size: |
f20x110
mm |
|
TMP36 Temperature
Sensor |
Thermistor
IC |
|
Range: |
-40 to 120°C |
|
Accuracy: |
± 0.1°C |
|
Resolution: |
0.1°C |
|
Sensor Size: |
f10x110
mm |
|
SCT1121 Conductivity
Sensor |
Pulse-electrode
cell K=0.1,1.0/cm |
|
Range: |
0 to 500ms/cm |
|
Accuracy: |
± 1.5% of
reading |
|
Resolution: |
0.04 uS/cm |
|
Methods: |
USEPA 120.1 Standard Method
2510-B for wastewater |
|
Sensor Size: |
f11x110
mm |
|
SCT1122 Conductivity
Sensor |
2-electrode
cell with auto-ranging |
|
Range: |
0 to 100, up to
1000 mS/cm |
|
Accuracy: |
± 0.5% of
reading, or 0.1% of step whichever is greater |
|
Resolution: |
0.04 uS/cm to 0.1
mS/cm (range-dependent) |
|
Salinity
Sensor Type; |
Calculated
from conductivity and temperature |
|
Range: |
0 to 70 ppt |
|
Accuracy: |
± 1.0% of
reading or 0.1 ppt, whichever is greater |
|
Resolution: |
0.01 ppt |
|
Methods: |
USEPA 120.1 Standard Method
2510-B for wastewater |
|
Sensor Size: |
f50x300
mm |
|
SCT1130 Conductivity
Sensor |
2-electrode high
frequency attenuation |
|
Range: |
0 to 30% TDS |
|
Accuracy: |
± 0.1% FS |
|
Resolution: |
0.1% |
|
Sensor Size: |
f24x300
mm |
|
Mud1204 Concentration
Sensor |
high
frequency attenuation |
|
Range: |
0 to 60% TDS |
|
Accuracy: |
± 0.1% FS |
|
Resolution: |
0.1% |
|
Sensor Size: |
f24x300
mm |
|
Turb4210D
Turbidity Sensor |
90° dispersion |
|
Range: |
0-2000 NTU |
|
Accuracy: |
± 0.5% of
reading, ± 0.1% FS whichever is greater |
|
Resolution: |
1 NTU |
|
Methods: |
Turb.90d 4210_640 meets
USEPA 180.1 Turb.90d 4210_880 meets ISO 7027 / EN
27027 |
|
Sensor Size: |
f50x300
mm |
|
Turb4210DU
Turbidity Sensor |
90° dispersion |
|
Range: |
0-2000 NTU |
|
Accuracy: |
± 0.5% of
reading, ± 0.1% FS whichever is greater |
|
Resolution: |
0.01 NTU |
|
Methods: |
Turb.90d 4210_640 meets
USEPA 180.1 Turb.90d 4210_880 meets ISO 7027 / EN
27027 |
|
Sensor Size: |
f50x300
mm |
|
Turb4210DTU
Turbidity Sensor |
90° dispersion |
|
Range: |
0-200 NTU |
|
Accuracy: |
± 0.5% of
reading, ± 0.1% FS whichever is greater |
|
Resolution: |
0.001 NTU |
|
Methods: |
Turb.90d 4210_640 meets
USEPA 180.1 Turb.90d 4210_880 meets ISO 7027 / EN
27027 |
|
Sensor Size: |
f50x300
mm |
|
MLSS4210D
Turbidity Sensor |
90° dispersion |
|
Range: |
0-10,Max to
100g/L |
|
Accuracy: |
± 0.5% of
reading, ± 0.1% FS whichever is greater |
|
Resolution: |
0.1mg/L(HBD5) 0.05%FS(HBD4) |
|
Methods: |
Adapted from
<Sewage and Industrial Wastes,31,1159(1959) |
|
Sensor Size: |
f50x300
mm |
|
pH Sensor
Type: |
Glass
combination electrode |
|
Range: |
0 to 14 pH |
|
Accuracy: |
±0.2 pH |
|
Resolution: |
0.01 pH |
|
Sensor Size: |
f10x110
mm |
|
ORP Sensor
Type: |
Platinum
button |
|
Range: |
-999 to +999 mV |
|
Accuracy: |
± 10 mV |
|
Resolution: |
0.1 mV |
|
Sensor Size: |
f10x110
mm |
|
ISE Sensor
Type: |
Electrochem |
|
Range: |
Refer
to sensor details |
|
Acc |